Hook-It® (VNH)

A wrap-around, military-grade, flame-retardant cable management solution that utilizes a Velcro® hook-and-loop closure system for quick re-entry.

Drawing Number(s): ZT97-13-006

Hook-It® (VNH)
RoHS Military Grade

Select product options

+ Please fill in at least one field.
Selected Part Number:ZT97-13-006-0.5-B-B
Get A Quote
WARNING: Cancer and Reproductive Harm | www.P65Warnings.ca.gov

Overview

Hook-It® (VNH)
  • VNH-23 jacketing meets Mil-C-20696 / Mil-PRF-20696, Type II, Class 2
  • Nylon Velcro® hook-and-loop requires no tools for installation
  • 1” diameter offers a National Stock Number (NSN) for easy procurement

Hook-It® (VNH) is a cable management system that pairs the VNH-23 military-grade jacketing with a nylon Velcro® closure system. The VNH jacketing is a 0.023” thick PVC-coated nylon material that is flame retardant and waterproof. This jacketing is ideal for wires or cables exposed to rugged conditions that need strong bundling and protection.

The Velcro® is one of the easiest closure systems with requiring no tools for installation. The nylon hooks and loops engage together to provide a secure closure, but can be easily pulled apart for quick access to wires or cables inside. The Velcro® conforms to GSA specification A-A-55126, Type II, Class 1. The Velcro® is sewn to the VNH jacketing with a black nylon thread.

Hook-It® (VNH) is engineered for applications that desire lasting, durable protection from harsh environmental conditions. Hook-It® (VNH) is offered in diameters ranging from 0.5” to 8”, with custom shapes and sizes available upon request. The 1” diameter also offers an NSN for easy procurement. The operational temperature range is -65°F to 171°F (-54°C to 77°C).

Specifications

Overall Performance

  • Diameter: Custom
  • Closure: Hook-and-Loop (Nylon)
  • Material: VNH-23
  • Hook and Loop: 5/8" / 1"
  • Maximum Operating Temperature: 171°F
  • Minimum Operating Temperature: -65°F
  • RoHS: RoHS-10

VNH-23

  • Mil-Spec: Mil-C-20696 / Mil-PRF-20696, Type II, Class 2
  • Durability: Better
  • REACH: Compliant
  • Flame Retardant: FED-STD-191 Method 5903
  • Thickness: 0.023"
  • Maximum Operating Temperature: 171°F
  • Minimum Operating Temperature: -65°F
  • RoHS: RoHS-10
  • Shelf Life: 36 Months
  • Tensile Strength: 225 Warp; 225 Fill

Hook-and-Loop (Nylon)

  • Mil-Spec: GSA Spec A-A-55126, Type II, Class 1
  • REACH: Compliant
  • Thickness: 0.125"
  • Material: Nylon
  • Maximum Operating Temperature: 200°F
  • Minimum Operating Temperature: -70°F
  • RoHS: RoHS-10

Nylon Thread

  • Mil-Spec: VT-295, Type II, Class A
  • REACH: Compliant
  • Closure: Sewn
  • Elongation: 26% max
  • Flame Retardant: Flame retardant, melts
  • Material: Nylon Thread
  • Material: Bonded, twisted Polyamide filaments
  • RoHS: RoHS-10
  • Tensile Strength: 11.8 lbs min.
Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © The Zippertubing® Company, Chandler, Arizona.

Similar products

Zip-On® (63) Zip-On® (PFR) Z-Coil™
NAME ZIP-ON® (63) ZIP-ON® (PFR) Z-COIL™
DESCRIPTION A wrap-around cable bundling and protection solution that has a PVC, military-grade jacket that is abrasion and fluid resistant, with a pressure track. A wrap-around cable protection solution that is flexible, resistant to abrasion and fluids, and has a pressure track closure. A self-closing wire bundling and protecting sleeve made from self-extinguishing PET material that is ideal for high-volume requirements.
Closure Z-Track (PVC) Z-Track (PFR) Self-Closing
RoHS RoHS-10 RoHS-10 RoHS-10
Abrasion Resistance Best Best Better
Installation Type Wrap-Around Wrap-Around Wrap-Around
Purpose Sleeve Sleeve Sleeve
Min Temperature Low Moderate Extreme
Minimum Operating Temperature -4°F -34°F -58°F
Max Temperature Moderate Low Moderate
Maximum Operating Temperature 221°F 194°F 302°F
Flexibility Better Best Best
View View View

Hook-It® (VNH)

A wrap-around, military-grade, flame-retardant cable management solution that utilizes a Velcro® hook-and-loop closure system for quick re-entry.

Drawing Number(s): ZT97-13-006

  • VNH-23 jacketing meets Mil-C-20696 / Mil-PRF-20696, Type II, Class 2
  • Nylon Velcro® hook-and-loop requires no tools for installation
  • 1” diameter offers a National Stock Number (NSN) for easy procurement
  • Features

  • Ideal for rugged conditions such as warehouses or industrial industries
  • Velcro® hook-and-loop closure allows for quick and easy access to wires or cables
  • Operational temperature range is -65°F to 171°F (-54°C to 77°C)
  • Benefits

  • Military-grade jacketing that is flame retardant and waterproof
  • Wrap-around solution allows for installation without disassembly
  • Lightweight while still providing durable protection
  • Hook-It® (VNH)

    Hook-It® (VNH)

    MATERIAL SPECIFICATIONS

    Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © The Zippertubing® Company, Chandler, Arizona.

    Recently viewed