EMI-101 Part 1 – EMI Signal & Field Types

Preface | Part 1 | Part 2 | Part 3 | Part 4 | Part 5 | Conclusion

Unwanted EMI/RFI signals are generated in two ways when electrons flow through a conductor. They generate both a magnetic field (H-Field) and a radiated electric field (E-Field). Both forms of energy can be disruptive to sensitive electronics to some degree.

To understand these unseen forms of energy and how each may impact an electronic system, it is desirable to visualize each type to understand how they might impact other systems around them.

Bar Magnet H Fields - EMI 101 - EMI Signal

Magnetic Fields (H-Fields) emanating from a linear conductor can be visualized like a bar magnet. In a magnet, one pole is positive and one pole is negative. Magnetic field lines emanate from the positive pole and loop out away from the magnet to the negative pole. The closer the field lines are to the magnet, the closer together they are and in turn the stronger they are. As the distance from the magnet increases, the field lines get further and further apart from one another and the result is that the field strength is weaker as the distance increases. Field strength drops with the square of the distance. The effect of an H-field on the surrounding environment is also a function of the amount of power flowing through the conductor. Power (amperage) flowing through a conductor dictates how far away the H-field extends from the conductor and how strong the field is. The degree of impact an H-field will have on surrounding systems is also a factor of the physical orientation of the two systems. If a low-voltage signal circuit conductor runs parallel and fairly close to the high-power conductor generating a significant H-field, then the signal circuit conductor will be immersed in the intense field lines over a significant distance and the disruption of the signal circuit will be significant. If it were to cross the high-power conductor at 90 degrees, then the field line exposure would be minimized and the impact or disruption would be smaller, or possibly insignificant. The general rule for minimizing known H-field problems is to increase conductor separation distance and avoid parallel runs as much as possible.

Motor with large wires

Examples of large H-field emitters are conductors running to large motors and relays which demand high current loads. These types of fields generally occur at lower frequency ranges of typically 300 KHz or less.

Electric Fields (E-Fields) are different than H-fields in several ways. They typically extend for great distances from the radiating source, unlike H-fields, and they can impart an electrical charge onto unprotected cabling through electromagnetic induction, electrostatic coupling, or conduction.

Under floor cable runs

Linear cable runs are essentially antennas that can transmit and receive signals. Cables are highly susceptible to picking up unwanted stray signals moving through the environment. E-field noise can be visualized as a wave, not unlike those created when dropping a pebble into a pond. The wave radiates away from the generating source in all directions and dissipates its energy very slowly. The distance that the wave travels before dissipating is a function of the power level that the radiating system is generating. The wavelength of an electric field varies with frequency range. At low frequencies the wavelengths are quite long and as the frequency range increases the wavelengths get shorter and shorter. Low-frequency wavelengths may be a kilometer long where as high-frequency wavelengths may be less than a centimeter long.

E-field noise pebble in pond

So why is that important? Imagine a low-frequency wave with a length of one kilometer. If you have a system operating in a metal building with a six meter wide door open to the environment, when the long wave passes by, only ½ of 1 percent of the total wave’s energy strikes the operating system. Chances are the operating system is not negatively impacted by this low level of energy striking the system because the energy imparted on the system is below the “upset threshold.” However, if the wave were a higher frequency wave with a wavelength of 1 meter, then the entire wave passes through the open door and the full energy associated with the wave strikes the system. Continued exposure to this higher frequency level may exceed the upset threshold of the operating system and may cause internal system data corruption. As the frequency range gets higher and higher, a progressively larger percentage of the wave energy strikes the susceptible system described.