Heat-Wrap®

Adhesive Closed, Wrap Around Heat Barrier, Up to 149°C

Heat-Wrap® is designed for moderate-to-high-temperature, low-cost, heat-barrier applications. Heat-Wrap® utilizes a high-performance Acrylic adhesive-closure system that provides excellent bond strength when combined with either Zippertubing's highly-flexible ALS-5 or medium-weight ALP-500 jacketing material.

The adhesive closure of this product provides not only a cost-effective solution, but is incredible easy-to-install on virtually any application. The adhesive has very good fluid resistance and will not degrade with exposure to ultraviolet light.

Product Specifications

Shelf Life 12 months

Available Attributes
Please call us at (855) 289-1874 for any custom needs. We have a solution for you!

Shape of Installation Round
Cable Diameter 0.25" 0.375" 0.5" 0.625" 0.75" 1.0" 1.125" 1.25" 1.375" 1.5" 1.625" 1.75" 1.875" 2.0" 2.125" 2.25" 2.375" 2.5" 2.625" 2.75" 2.875" 3.0" 3.125" 3.25" 3.375" 3.5" 3.625" 3.75" 3.875" 4.0"
Exterior Material ALP-500 ALS-5
Closure Adhesive
Material Color Aluminum/White

Material Specifications

ALS-5

Material Thickness 0.006"
Temperature Range -50° to 177°C (-58° to 350.6°F)
Tensile Strength 100 lbs/min (warp) | 50 lbs/min (fill)
Tear Strength 2.0 lbs/min (warp) | 2.0 lbs/min (fill)
Shelf-Life 60 months

Tape (High Temperature)

Shelf-Life 12 months, unbonded (Zippertubing)
RoHS Compliant
Release Liner Polycoated Paper Liner
Color Clear
Adhesion 150 oz/in. (to steel)
Shear Strength 300 grams @ +149°C for > 10,000 minutes (Alum. to Steel)
Flammability Fire Retardant
Solvent Resistance Very Good
U.V. Resistance Good
Temperature -40°C to 149°C Days/Weeks (-40°F to 300°F Days/Weeks) -40°C to 232°C Minutes/Hours (-40°F to 449°F Minutes/Hours)
Adhesive Thickness 0.005"
Adhesive Acrylic
Liner Thickness 0.004"

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitabilituriy for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2018 The Zippertubing® Company, Chandler, Arizona.