05/22/18

Print

DATASHEET

ISO/TS 16949 ISO 9001

7150 W. Erie St, Chandler, AZ 85226, USA

(855) 289-1874

sales@zippertubing.com

www.zippertubing.com

 product image

Z-Shield® (5080)

Fire-Retardant Polyurethane Jacket with Z-5080-CN EMI Shield

Z-Shield® (5080) is a wrap around EMI shielded jacket made of fire-retardant Polyurethane film, flame retardant Z-5080-CN EMI shielding cloth, and an adhesive closure. This combination provides good electromagnetic shielding of wires and cables in applications requiring outstanding flexibility, flammability to UL224, VW-1, and good dielectric strength.

This product is extremely useful in electronics applications where space may require a thin and flexible shielding. Z-Shield® (5080) can be configured to fit most Round, Flat or Rectangular cable configurations and is available with or without a drain wire installed.

This product has an operational temperature range of -30° to 80°C (-22° to 176°F).

Product Specifications

Shelf Life 12 months
RoHS Compliant
Flammability UL224, VW-1

Available Attributes
Please call us at (855) 289-1874 for any custom needs. We have a solution for you!

Shape of Installation Flat Round
Cable Diameter 0.25" 0.375" 0.5" 0.625" 0.75" 0.875" 1.0" 1.25" 1.375" 1.5" 1.625" 1.75" 1.875" 2.0" 2.25" 2.5" 2.75" 3.0" 3.25" 3.5" 3.75" 4.0" 4.5" 5.0" 5.5" 6.0"
Exterior Material PFR-8235
Shielding Z-5080-CN - w/ No Ground Z-5080-CN - w/ 15 AWG Ground
Closure Adhesive
Material Color Black

Material Specifications

PFR-8235

RoHS Compliant
Shelf-Life 60 months
Material Thickness 0.007"
Temperature Range -53° to 80°C (-63.4° to 176°F)
Flame Retardant UL-510
Dielectric Strength 800 volts/mil
Elongation 725% at break

Z-5080-CN

Material Thickness 0.009"
Temperature Range -30° to 121°C (-22° to 249.8°F)
Tensile Strength 61.7 lbs/in (warp); 33.1 lbs/in (fill)
Flame Retardant UL94 VTM-O
Surface Resistivity <0.1 omh/sq.
Elongation 24% (Warp); 31% (Fill)
RoHS Compliant
Shelf-Life 60 months
Shielding Effectiveness Better
Z-5080 Shielding Effectiveness

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitabilituriy for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2018 The Zippertubing® Company, Chandler, Arizona.