Z-Shield® (2L)

Drawing No. ZT93-04-007

 product image

Dual Wall Fire-Retardant Polyurethane Jacket with Z-3250-CN EMI Shield

Z-Shield® (2L) consists of two layers of fire-retardant Polyurethane film encapsulating a Z-3250-CN EMI shield cloth, and utilizes a double adhesive closure. The dual layer of Polyurethane film creates a finished jacket that has an inner dielectric spacer and will meet UL224, VW-1 flammability requirements.

Z-Shield® (2L) provides outstanding electromagnetic shielding of wires and cable bundles. It is highly flexible, and provides good dielectric strength and mechanical protection of the cable. The product can be configured for Round; Flat or Rectangular cable shapes and is available with or without a drain wire.

This product has an operational temperature range of -45° to 80°C (-49° to 176°F).

Product Specifications

RoHS
Compliant
Shelf Life
12 months
Flammability
UL224, VW-1

Available Attributes
Please call us at (855) 289-1874 for any custom needs. We have a solution for you!

Shape of Installation
Flat Round
Cable Diameter
0.5" 0.75" 1.0" 1.125" 1.25" 1.375" 1.5" 1.625" 1.75" 2.0" 2.5" 3.0" 3.5" 4.0"
Exterior Material
PFR-8235 - 2 Layers
Shielding
Z-3250-CN - No Ground Z-3250-CN - w/ 15 AWG Ground Z-3250-CN - w/ 27 AWG Ground
Closure
Adhesive
Material Color
Black

Material Specifications

PFR-8235

Temperature Range
-53° to 80°C (-63.4° to 176°F)
RoHS
Compliant
Material Thickness
0.007"
Elongation
725% at break
Dielectric Strength
800 volts/mil
Shelf-Life
60 months
Flame Retardant
UL-510

Z-3250-CN

Shelf-Life
60 months
Minimum Operating Temperature
-40
Elongation
27%
Maximum Operating Temperature
250
Tensile Strength
74-79 lbs/in
RoHS
Compliant
Shielding Effectiveness
Better
Material Thickness
0.004"
Base Fabric
Polyester Taffeta Fabric
Coating
Nickel Over Copper
Surface Resistivity
<0.1 ohms/sq
Shielding Effectiveness

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitabilituriy for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2018 The Zippertubing® Company, Chandler, Arizona.