10/16/18

Print

DATASHEET

ISO 9001 / IATF 16949

7150 W. Erie St, Chandler, AZ 85226, USA

(855) 289-1874

sales@zippertubing.com

www.zippertubing.com

Shrink-N-Shield® (HW)

Drawing No. ZT04-18-002

 product image

One-Step Shielding and Jacketing Tubing, 3:1 Shrink Ratio, Polyolefin, Heavy Wall Tubing

Shrink-N-Shield (HW) combines two proven technologies into a single, easy to install product for adding EMI shield protection to wire and cable bundles with diameters of 1/2" and less. Makes adding an EMI shield or secondary EMI shielding to wire and cable a snap. This product is comprised of SAE-AMS-DTL-23053/15 (w/o the adhesive layer) heat shrink tubing and Zippertubing's Z-3250-CN conductive cloth which has outstanding shielding properties. It is ideal for applications where thick, heavy wall insulation is needed for superior mechanical protection. This product has an operational temperature range of -55 to 110°C. This product is supplied in four foot long sticks.

Product Specifications

RoHS
Compliant
Shelf Life
60 months
Minimum Operating Temperature
-40 ° F (-40 ° C )
Maximum Operating Temperature
230 ° F (110 ° C )

Available Attributes
Please call us at (855) 289-1874 for any custom needs. We have a solution for you!

Shape of Installation
Round
Diameter Before Shrinkage
0.35" (#01) 0.40" (#03) 0.75" (#05) 1.1" (#07) 1.5" (#09)
Unit Length
4 ft. Sticks
Exterior Material
Heavy Wall Heat Shrink (3:1)
Shielding
Z-3250-CN
Material Color
Black Red
Shield Bonding
Nitrile Adhesive

Material Specifications

Heavy-Wall-Polyolefin

Flammability
Flame retardant (UL 486)
Electrical
1 Kv @ 90C 2500v (continuous)
Maximum Operating Temperature
230
Elongation
per AMS DTL-23053/15
Minimum Operating Temperature
-40
Tensile Strength
per AMS DTL-23053/15

Z-3250-CN

Shelf-Life
60 months
Minimum Operating Temperature
-40
Elongation
27%
Maximum Operating Temperature
250
Tensile Strength
74-79 lbs/in
RoHS
Compliant
Shielding Effectiveness
Better
Material Thickness
0.004"
Base Fabric
Polyester Taffeta Fabric
Coating
Nickel Over Copper
Surface Resistivity
<0.1 ohms/sq

Nitrile Adhesive

Base
Synthetic Elastomer
Solvent
Acetone and Cyclohexanone
Flash Point
0 ºF (-18 ºC)
Viscosity
200 - 325 cps
Form
Light Tan liquid, (wet and dry)
Shielding Effectiveness

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitabilituriy for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2018 The Zippertubing® Company, Chandler, Arizona.