Zippertubing has been building quality products and solutions since 1957 image Building Quality Products & Solutions Since 1957
SHX-2 (SnCu) with Drawing Number: 3103-2

SHX-2 (SnCu)

Specification No. 3103-2

Tin Plated Copper Wire EMI Shielding Mesh, 2-Ply

  • Electrical resistance 936.51 ohms
  • Extremely flexible & lightweight
  • Non flammable

Raw materials are not sold separately, please contact the sales department for any special requirements.

Material Specifications

Available Attributes

Material Color Bright Tin

SHX-2 (SnCu)

Temperature Range -55° to 204°C (-67° to 399.2°F)
Wire Size 36 AWG
Abrasion Resistance Good
Electrical Resistance 936.51 ohms/lb @ 20C
Tensile Strength .785 lbs
RoHS Compliant
Ratings ASTM B33-94, MS3304 Type 1
Openings Per Inch 10-13
Configuration Single knitted tube, flattened
Shielding Effectiveness Good

Attenuation data was derived using procedures defined in MIL-STD-285 and tested by scientific applications international corporation (SAIC) EMI laboratories, San Diego, California

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2018 The Zippertubing® Company, Chandler, Arizona.

SHX-2 (SnCu) is a flexible 2 layer knitted wire mesh EMI shielding material that is made of tin plated, copper wire. The knitted mesh design creates a highly flexible shield that unlike many tubular braids will not change attenuation performance when articulated. The knitted wire mesh maintains constant window spacing during cable assembly movement. The material is highly conductive, lightweight and is ideal for airborne applications where lightning strike grounding is required. The mesh can be added to most Zippertubing jacket materials to create an easy to install Zip-on EMI shielded assembly.