AST-25

 Anti-Static Cable Jacket, 25 Mil
AST-25 is a conductive Carbon loaded, fire retardant, PVC coated Polyester fabric material. It is an excellent abrasion jacket combined with anti-static properties. A properly grounded AST-25 jacket has an electrical resistance of less than 25 meg-ohms and will eliminate static charge buildup and prevent potentially explosive conditions or damage to static sensitive electronic devices. AST-25 can be used to protect electrical cabling in clean room environments from static charge buildup common with most other plastic insulation materials. The materials rugged construction makes it ideal for fabricating anti-static airflow ducting for use in tunnels, mines, or electronics ventilation systems. AST-25 is available in the classic Zippertubing wrap around design and can be closed with a variety of closure devices. The operational temperature range for AST-25 is -20 to 75ÂșC.

Features & Benefits:
  • Anti-Static Material, < 120 Megohms
  • Excellent Abrasion & Environmental Properties
  • Flame Retardant
  • Good Flexibility
  • -20 to 75 C Operational Limit


  • Thickness (inch)Material TypeTemp Range (°C)Flame RetardBreak StrengthRatingsDielectric (volts/mil)
    .025"Carbon PVC/Polyester-20 to 75NF M 82-011450 Warp; 450 FillCommercialAnti-Static, <120 Megohms

    EMI Shields AvailableFlexibilityFluid ResistCable TypesSizesColorsClosures Available
    AllMediumGood, Mild SolventsRound, Flat & Rect3/8" & Up Round, 1-1/4" & Up Flat Flat & Rect, 1-1/4" & UpBAll



    For more information contact Customer Support: info@zippertubing.com

    Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters, which are beyond the control of the Zippertubing Company. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and Patents Pending. Copyright 2009 The Zippertubing Company, Los Angeles, California.